Dear Consumer;

Thank you for purchasing Supersonic XM-4600B. Supersonic XM-4600B has a relatively practical usage. The perception range is sufficient to meet your criteria. Make exercises with your detector as much as possible. Try to understand completely how to make ground balancing.

Switching on the Detector

Switch. the detector on as described below before starting the searching process.

4600-02.jpg

After assembling the Coil sticks and connecting the cables hold the the Coil at about 40 centimeters high above the ground and:

Switch the Detector on by pressing the ON/OFF button and then press the RESET ALL METALS button

Note that the indicator will be centrally aligned.

Let the device warm up about 40-50 seconds before begin ground balancing..

While the device is warming up you can prevent the slippages that become at the indicator by pressing RESET button.

Ground Balance

In order to remove the mineral effect of the ground, GROUND BALANCE is adjusted as described below. While Ground Balancing the device must be at ALL METALS position.

 

4600-03.jpgAfter switching the device on, take the GROUND FINE BALANCING button to the middle position. And:

 

1. Move the coil down to a 5-10 centimeter-height from the ground

2. If there is a sound coming from the device, move the coil 40 centimeters up.

3. Take the GROUND BALANCE button to the 2nd position and press the RESET ALL METALS button while

holding the coil at the same height.

4. Move the coil down to a 5 centimeter-height from the ground.

5. If there is still a sound coming from the device, move the coil 40 centimeters up

6. Take the GROUND BALANCE button to the 3rd position and press the RESET ALL METALS button.

7. Move the coil down to a 5 centimeter-height from the ground again.

8. If there is still a sound coming from the device, move the coil 40 centimeters up.

9. Take the GROUND BALANCE button to the 2nd position and press the RESET ALL METALS button.

10. Move the coil down to a 5 centimeter-height from the ground again.

11. If the sound stops GROUND BALANCING is completed and searching process can get started. But if the sound still exists the steps described above are repeated increasing the position of the GROUND BALANCE button one level at every repeat.

Ground Fine Balance

Ground Balancing will be eventuated surely at a position from 1 to 12. There can be slippages at the indicator despite of the Ground Balancing has been done. These slippages can be overcome with the GROUND FINE BALANCE button located left below of the device.

 

POSITION 1

4600-04.jpgAfter the Ground Balancing if there is no sound but the indicator moves to the left:

1. Move the coil 40 centimeters up

2. Turn the GROUND FINE BALANCE button at the arrow direction shown in the figure.

3. Press the RESET ALL METALS button.

4. Move the coil down to a 5 centimeter-height  from the ground.

If the indicator still moves to the left, repeat these steps until the indicator stays still or is in the least sliding position. If you provide one these conditions begin searching.

POSITION 2

4600-05.jpgAfter the Ground Balancing if there is no sound but the indicator moves to the right:

1. Move the coil 40 centimeters up

2. Turn the GROUND FINE BALANCE button at the arrow direction shown in the figure

3. Press the RESET ALL METALS button

4. Move the coil down to a 5 centimeter-height from the ground.

If the indicator still moves to the left, repeat these steps until the indicator stays still or is in the least sliding position. If you provide one these conditions begin searching.

 

Searching

The ground balance that you've done would give the result at the ALL METALS position. Therefore you're your searches at this section.

 

 

Hold the coil at 15 centimeter-height and go forward while moving it left and right harmoniously like a brushing process. There should not be any place on the ground that the coil doesn't pass over.

 

1.While searching at the ALL METALS position:

Ü If there is a sound coming from the device and the indicator moves to the right, area contains metal or lots of minerals. The content of the signal should be well evaluated. The ground may contain cubic substances or high dense minerals and may seem like contain metal. orderto understand the content of the signal that technique is applied: move the coil beside of the signal producing area and take the GROUND BALANCE button the 3rd position, then press the RESET button and release it. After that, pass the coil over the signal producing area one more time. If you have the signal again this area contains metals. If you don't have any signals the area contains minerals. In this way you remove the mineral effect of the ground.

 

Again searching at  ALL METALS positon:

Ü The indicator moves to the left witout any sound, there can a gap at the area. The indicator stays at this position till the end of the gap. After the gap the indicator moves to the middle position. To make it definite that the ares contians gaps, first move the coil far beside of the area and take the GROUND BALANCE button back to the position 1. Than press the RESET button and release it. After that move the coil over the signal producing area. If the indicator still moves to the left, it is certain that he area has a gap. If the it has no gap, the indicator doens't move to the left after this process. It stays at the middle position or moves to the right with a sound signali, so you understand that the thing detected is because of a mineral effect.

 

2. Searching at the INDICATOR PICKING position, when you coincide with a metal, if the metal is worthless, the indicator stays at the middle position and the device gives a sound signal. If it is valuable, the indicator moves to the right with a sound signal. If it is a half-valuable metal such as steel, sheet, galvanize or nickel, before the action it gives a sound. After the sound the indicator moves to the right. Horseshoe and nail are similar to the steel therefore makes a similar effect.

         

3.Searching at the METALS position, worthless metals aren't detected. The indicator moves to the right with a sound signal at valuable metals. You are able to make a search directly at this section or you can test the metal you detected at the ALL METALS section.

While doing RESET process at the Indicator Picking and Valuable Metals section, Hold the coil at 15 centimeter-height, press the RESET button. Then move the coil to the right and press the RESET button. After that move the coil over the metal like a brushing process. Do not hold the coil over the metal too long.

         

4. If you think that the detected metal is GOLD, move the coil to the right at the same height, switch to the GOLD PICKING position and press the RESET button of this position. If the indicator shakes silently in the middle, when you  pass the coil over the metal one more time, the metal is gold. But if it moves to the right it is another valuable metal. When  move the coil over the substances such as steel, nickel plated metal or galvanized sheet metal, if the device is in GOLD PICKING position, first the indicator moves to the left slowly, then moves to the right with a sound signal. Horseshoe and nail are similar to steel and can make a similar effect. 

 

NOTE: At the GOLD PICKING position the device is very sensitive to the ground, so while checking the metal never move the coil upward down. Keep the 10 centimeter-height constant. When you move the coil downwards the indicator may move to the left and when you move it upwards it may move to the right with a sound signal.

 

Attention

DO NOT HOLD THE COIL OVER ANY METAL TOO LONG.

Dept Detection

Dept Detection is done at the ALL METALS position.  While doing the dept detection at 5 or 6 meters position, it is too important to understand the dept of the signal, as a matter of preventing the waste of time and labour force. The following technique is applied for the Dept Detection:

For instance, if there is a distance of 3 meters between the start and end point of the signal produced from the ground;

Decrease the dept pf the device to 1 meter and pass the coil over the point and checked;

If there is no change at the dept of signal (the distance between the start and end point is nearly 3 meters), there is a huge metal close to the ground.

But if the signal area becomes smaller and the sound becomes weaker, it is understood that the metal is at the deep.

 

4600-06.jpg

4600-07.jpg

Strong signal and bigger signal area are clues of bigger metal. But the best way of figuring the dept out is to decrease the device dept and test again. The size of the metal can be figured out from size of the area that the signal is produced on.

 

Searching at 1 meter position, if there is an average of 1 meter signal area, a 2 meter-dept excavation is required.

 

Important Notes

Have the device a perfect Ground Balancing. Make a dept detection. Try to figure out the kind of metal by the help your experience and device. Continue digging until you reach your goal.

 

 

Ü Your device has a 6 meter-perception range.

But if the duration of metal being inside the ground gets longer, the perception range gets longer too.

Ü Do not knock the coil to hard objects.

Ü Do not disassembly the device by yourself or has it disassembled anyone else expect the authorized services. 

Approximate Depth Table

 

There would be an increase at these values if the duration of being underground increases.

 

Battery Life and Charging

Don't worry about changing the batteries at this device. You can use your device by charging it as long as you want with the long life capacity charging system.

When the battery of your device is low, Cursor indicator will be place minus mark. After this led signal you can make maximum 10 minutes searching and you should charge it.

 

 

 

If you don't use your device for a long time, check the batteries at certain periods of time (for instance one times a half month) and don not let it be emptied completely. There can be a decrease at the performance of a completely emptied battery.

Before charging shut down your device

Avoid of using different charging devices. Charging devices that charge quickly may shorten your battery's life.

10 hours of average charging duration  

12 hours of usage to empty the battery.

                                     Searching Tips

While you make the search confirming the rules at the figure left,if you meet with any metals, device will give a reaction both with sound and led.

 

 

 

After the ground balancing if there no sound coming from device you can begin searching.

 

 

 

Hold the coil at 10 centimeter-height and go forward while moving it left and right harmoniously like a brushing process. There should not be any place on the ground that the coil doesn't pass over.